Electrical Machines Online Test


Correct Answer: 2 points | Wrong: -1 point
Grades: A* (100% score) | A (80%-99%) | B (60%-80%) | C (40%-60%) | D (0%-40%)
advertisement

Here is the complete list of test quizzes on Electrical Machines.

1. When a constant power output is desired to maintain __________

Question 1 of 50

2. If the pu impedance of a single phase transformer is 0.01+j0.05, then its regulation at p.f. of 0.8 lagging will be?

Question 2 of 50

3. A synchronous machine with its field winding on stator and polyphase armature winding on rotor. At steady state, its air gap field is?

I. stationary w.r.t. stator 
II. rotating at double the speed Ns w.r.t. rotor
III. rotating in direction opposite to rotor 

Question 3 of 50

4. While the operation of dc motor, there are sparkings at the commutation observed. These can be happening due to ________

Question 4 of 50

5. A 10 kVA, 400/200 V, 1-phase transformer with 2% resistance and 2% leakage reactance. It draws steady short circuit current at which angle?

Question 5 of 50

6. The rotor mmf per pole in the 3-phase, 4-pole induction motor varied with slip is?

Question 6 of 50

7. A synchronous machine with its field winding on stator and polyphase armature winding on rotor. At steady state, its air gap field is?

Question 7 of 50

8. At steady state operation in a 3-phase synchronous generator. (where Tem is developed electromagnetic torque developed in the machine and Tpm is the prime mover torque.)

Question 8 of 50

9. With the alternator running at rated terminal voltage Vt, at rated current Ia = 1 per unit. What happens if load current is reduced to zero, if it was operating at lagging power factor?

Question 9 of 50

10. The rotor power input of 3-phase induction motor is 15 kW at a slip of 5%. The mechanical power developed at the shaft is?

Question 10 of 50

11. Voltage induce in the induction motor is highest at __________

Question 11 of 50

12. For a 4 pole 200 V, 20 A dc generator running at the rated rpm with no load will be ________

Question 12 of 50

13. I. Pulse transformers use soft ferrites.
II. The transformers used in the radio recievers use air core.

Question 13 of 50

14. Which of the given losses are directly proportional to square of speed?

Question 14 of 50

15. In the following circle diagram, what is CC'?
OG is the rated torque in the circle diagram

Question 15 of 50

16. Three phase voltages are applied to the three windings of an electrical machine. If any two supply terminals are interchanged, then the rotating MMF wave _____________

Question 16 of 50

17. A synchronous machine with its field winding on rotor and polyphase armature winding on stator. At steady state running condition, its air gap field is?

I. stationary w.r.t. stator
II. rotating at double the Ns w.r.t. rotor
III. rotating at -Ns w.r.t. rotor
IV. stationary w.r.t. rotor.

Question 17 of 50

18. Which of the following statements are correct regarding individual phase MMF in rotating machines?

Question 18 of 50

19. If the torque is in the direction of rotation, the DC machine acts as ________

Question 19 of 50

20. Which of the following is a shortcoming for using parallel connected transformers?

I. Reliable loading
II. Increased capacity of power system
III. Reducing the capacity of substation
 

Question 20 of 50

21. The EMF equation e = NωrΦsinωrt is applicable to ____________

Question 21 of 50

22. For 3-phase induction motor, as load increases from no load towards the full load, torque _______ slip.

Question 22 of 50

23. Consider a 3-phase cylindrical-rotor alternator.

A. E.m.f. generated by armature reaction lags armature current by 90°.
B. Air gap voltage leads the field flux by 90°
C. Air gap voltage lags the field flux by 90°    
D. Armature reaction due to intermediate lagging p.f is partly cross magnetizing & partly magnetizing

Question 23 of 50

24. The magnitude of rotating flux _____________ at all instants of time.

Question 24 of 50

25. The given variable losses are 5kW fr a 500 KVA, 11 kV, 3-phase star connected alternator having armature resistance of 4 ohms. Calculate the current at which maximum efficiency occurs?

Question 25 of 50

26. When a transformer winding suffers a short circuit, then inter turns of the same winding experience ______ forces.

Question 26 of 50

27. In case of a power transformer, the no load current in terms of rated correct is?

Question 27 of 50

28. Mark the correct order for the external characteristics of compound generators from the below graph.
Over compounding provides maximum voltage difference at no load in given figure

Question 28 of 50

29. The voltage drop at brush-commutator contact is variable (1-2V) and dependent of armature current.

Question 29 of 50

30. In a DC machine, z, p, Ia and a are respectively the number of conductors, number of poles, armature current and number of parallel paths. The peak value of fundamental component of armature MMF wave is ____________

Question 30 of 50

31. Alternator compounding characteristic is obtained by _________

Question 31 of 50

32. Which of the following statements support the ideal transformer features?

I. Zero winding resistance
II. Constant permeability
III. Constant core losses

Question 32 of 50

33. While doing regular checks on the dc machine with the lap connected winding, it is reported to have ammeter fluctuations, this can be due to _________

Question 33 of 50

34. The brushless excitation and conventional DC excitation systems are comparable but one significant change is _______

Question 34 of 50

35. If the frequency is reduced by 50% for a 3-phase, 50 Hz induction motor having 4 poles. The slip at which the maximum torque occurs becomes _________

Question 35 of 50

36. Select the possible dc magnetization characteristics of permanent magnetic materials.

Question 36 of 50

37. In a synchronous generator, the frequency of the generated EMF depends on ___________

Question 37 of 50

38. Consider the below remarks for an alternator.

(i) An over excited machine is more stiff
(ii) Machine with longer air-gap is less stable than one with smaller air-gap

Question 38 of 50

39. When an induction generator is connected to an infinite bus, it _________

Question 39 of 50

40. Which type of slots are used in the construction of large size and small size induction motors respectively?

Question 40 of 50

41. The reactance vs slip is given by?

Question 41 of 50

42. What is the amplitude of rotating MMF produced as a result of m-phase currents flowing in m-phase windings? (where Fm is maximum MMF in any one phase, when current is maximum in that phase.)

Question 42 of 50

43. Which of the following informations are not obtained from short-circuit test?

I. Ohmic losses at rated current
II. Equivalent resistance and leakage reactance
III. Core losses
IV. Voltage regulation

Question 43 of 50

44. If the synchronous machine is loaded from floating conditions, the alternator begins to operate at __________

Question 44 of 50

45. Identify the armature characteristic of the dc generator.

Question 45 of 50

46. A 6-pole alternator with 36 slots carries a 2-phase distributed winding. Each coil is short pitched by one slot. The winding factor is given by _____________

Question 46 of 50

47. Mark the most appropriate phasor for the induction machine operation as motor.

Question 47 of 50

48. A dc motor is connected in the short-shunt configuration, but the series and the shunt windings get interchanged by mistake and the motor is connected to the rated voltage?

Question 48 of 50

49. Separately excited dc generators are used in __________

Question 49 of 50

50. A three phase induction motor is not self starting.

Question 50 of 50


 

Topic wise Test Quizzes on Electrical Machines

Electrical Machines tests, quizzes, and exams are great ways to learn and test your Electrical Machines skills. Whether you’re a beginner or experienced, challenge and boost your confidence with our engaging online quizzes on Electrical Machines Basics, Rotating Machine, Rotating Magnetic Field, DC Machines, DC Motors, Synchronous Machines, Synchronous Motor, Induction Machine, Armature Winding and Electrical Transformers. Start the Electrical Machines online test now!



Electrical Machines Certification Test

Electrical Machines Certification Test is a free certification exam. However, you need to score an A grade in each of the "Certification Level Tests 1 to 10" to be eligible to take part in this certification test. So, take all the "10 Tests" starting from Certification Level 1 upto Level 10, before taking the final Certification test.


Level 1 to 10 Tests:
Total Questions: 25, Total Time: 30 min, Correct Answer: 2 points, Wrong Answer: -1 point

Certification Test:
Total Questions: 50, Total Time: 1 hour, Correct Answer: 2 points, Wrong Answer: -1 point

Electrical Machines Internship Test

If you scored either Grade A* or Grade A in our Electrical Machines Internship Test, then you can apply for Internship at Sanfoundry in Electrical Machines.


Total Questions: 50, Total Time: 1 hour, Correct Answer: 2 points, Wrong Answer: -1 point

Electrical Machines Job Test

It is designed to test and improve your skills for a successful career, as well as to apply for jobs.


Total Questions: 50, Total Time: 1 hour, Correct Answer: 2 points, Wrong Answer: -1 point

Note: Before you get started on these series of online tests, you should practice our collection of 1000 MCQs on Electrical Machines .

Sanfoundry Scoring & Grading System

Sanfoundry tests and quizzes are designed to provide a real-time online exam experience. Here is what you need to know about them.

  • Scoring System: You get 2 points for each correct answer but lose 1 point for every wrong answer.
  • Grading System: Your grade depends on your final score and can be one of the following:

    • Grade A* - Genius (100%)
    • Grade A - Excellent (80% to 99%)
    • Grade B - Good (60% to 80%)
    • Grade C - Average (40% to 60%)
    • Grade D - Poor (0% to 40%)